View Categories

What is the mechanical property of VitroGel®? Can I adjust the stiffness?

< 1 min read

We test the elastic modulus (G’) of VitroGel® with a dynamic rheometer. The G’ depends on the hydrogel dilution and the cell culture medium used. The G’ of non-diluted VitroGel® High Concentration is around 4,000 Pa. If a higher hydrogel strength is required, please contact us at support@thewellbio.com for a customized hydrogel that can reach over 20k Pa.